Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 18(5): e0285849, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37228105

RESUMO

The joint work of the stomach and the small intestine plays a fundamental role in human digestion. In the stomach, food is turned into a semi-fluid mixture that is slowly released into the small intestine, where most enzymatic reactions occur, and nutrients are absorbed as they become available. This whole process is closely related to glucose homeostasis, mainly because of the appearance of glucose in the portal system and the energetic expenditure of the process itself. The current phenomenological-based model describes such effects of the digestive process on blood glucose concentration. It considers enzymatic and mechanical transformations, energetic expenditure, and the impact of macro-nutrients, fiber, and water on overall digestion and glucose absorption. The model estimates the rate of glucose appearance in the portal vein and is intended to be further integrated into existing models for other human organs and used in model-based systems such as an artificial pancreas with automated insulin delivery.


Assuntos
Glucose , Veia Porta , Humanos , Insulina , Intestino Delgado , Estômago , Glicemia
2.
J Theor Biol ; 530: 110883, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34478744

RESUMO

BACKGROUND: A good treatment for type 1 diabetes mellitus (T1DM) requires accurate measurements of blood glucose levels. Continuous glucose monitors (CGM) measure the glucose concentration in the interstitial fluid of the abdominal subcutaneous adipose tissue. However, glucose measured in the abdominal interstitial fluid does not represent blood glucose concentrations accurately due to the complex blood transport through the body and glucose diffusion in interstitial fluid. METHODS: To gain insight into this problem, a phenomenological-based semiphysical model (PBSM) of glucose transport by volumetric flow and diffusion from the bloodstream to interstitial fluid was constructed. A published 10-step modeling procedure was used to obtain a model for glucose transport time through the blood vessels and from the blood capillaries to the interstitial fluid, glucose diffusion within the interstitial fluid, and glucose diffusion through the semipermeable coating of the sensor needle. For this model, a healthy person is considered at rest with average parameters. RESULTS: The simulations performed using the PBSM allow obtaining the glucose transport time from the liver to the sensor needle. In this way, it is possible to reconstruct an accurate dynamic measurement of blood glucose from the measurements in the interstitial fluid of the abdominal subcutaneous adipose tissue. CONCLUSIONS: PBSMs with parameters interpretability illustrate the connection of glucose concentrations in the interstitial fluid with that currently in the blood. Implementing this model in a CGM will result in more reliable measurements of blood glucose levels for T1DM treatment.


Assuntos
Diabetes Mellitus Tipo 1 , Gordura Subcutânea Abdominal , Tecido Adiposo , Glicemia , Glucose , Humanos , Fígado
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...